axismd.ai
Haas Controller
Servo/Axis · Advanced · 30 - 90 min
Haas Alarm 1310 - Servo Drive Fault Code
Alarm 1310 indicates a servo drive has detected an internal fault condition and has shut down to protect itself. This alarm is triggered when the servo amplifier reports fault codes to the NGC control, typically due to overheating, overcurrent conditions, or drive hardware failures.
Haas Alarm 1310 - Servo Drive Fault Code
Servo Drive Fault Code
This alarm indicates that a servo amplifier has detected an internal fault condition and has shut down to protect itself or the motor. The servo amp communicates the fault code to the MOCON board via the serial communication link. The machine will not allow motion on the affected axis until the fault is cleared and the drive is reset. This is a protective alarm that prevents damage to the servo system.
Root Cause Summary
Alarm 1310 indicates a servo drive has detected an internal fault condition and has shut down to protect itself. This alarm is triggered when the servo amplifier reports fault codes to the NGC control, typically due to overheating, overcurrent conditions, or drive hardware failures.
Safety
Causes and Fixes
Check Drive Temperature Status
Navigate to CURRENT COMMANDS > DIAGNOSTICS > SERVO and observe the drive temperature readings for each axis. Normal operating temperature should be below 70°C.
Use the CTRL+ALT+D diagnostic screen to see real-time servo drive temperatures
Inspect Cooling System
Power down machine and check all servo drive cooling fans for proper operation. Clean heat sinks with compressed air and verify cabinet ventilation is not blocked.
Always power down and lockout before accessing electrical cabinet
Verify Ambient Conditions
Check that shop ambient temperature is within specification (typically 32-104°F) and ensure adequate clearance around electrical cabinet for airflow.
Install additional cooling fans if ambient temperature consistently exceeds 85°F
Reset and Monitor
After cooling system verification, press RESET and monitor drive temperatures during light machining operations to confirm thermal issue is resolved.
Call a technician if:
Prevention
Common Mistakes