Haas codes
HaasSystemIntermediate20-60 minutes

1322

Haas Alarm 1322 - Chip Conveyor Motor

Chip Conveyor Motor

This alarm indicates the chip conveyor motor has faulted or the motor overload protection has tripped. The MOCON board monitors the chip conveyor motor circuit through either a thermal overload relay or a motor status input and triggers this alarm when a fault condition is detected. The conveyor will stop operation but the machine can continue to run, though chip buildup may become an issue during extended operation.

Root Cause Summary

Alarm 1322 fires when the Haas NGC control detects the chip conveyor motor has failed to start within the expected timeframe, has tripped its thermal overload protection, or the control hasn't received proper run confirmation from the conveyor motor relay feedback circuit. This alarm is triggered by the control monitoring the conveyor motor status through dedicated I/O points and current sensing circuits.

Safety

  • LOTO required - chip conveyor motor may auto-start when M08 coolant is commanded if Setting 93 is enabled. Lock out main disconnect before reaching into conveyor trough.
  • Sharp chips present serious laceration hazard - wear cut-resistant gloves and use chip rake or hook tools, never hands, to clear jams.
  • Chip conveyors can contain heavy compacted chip masses - support conveyor belt/flights before releasing tension to prevent sudden release and pinch points.

Causes and Fixes

  1. 1

    Check Motor Overload Status

    Navigate to CURRENT COMMANDS > I/O and check the conveyor motor overload input status. Look for the conveyor thermal overload bit to be active.

    Ensure main power is locked out before accessing electrical components

  2. 2

    Reset Motor Overload

    Locate the conveyor motor starter in the electrical cabinet and manually reset the thermal overload relay by pressing the reset button on the motor starter.

    Allow 10-15 minutes cooling time before resetting if motor is hot to touch

  3. 3

    Check Motor Current Draw

    Use a clamp meter to measure motor current during operation. Compare against nameplate amperage - excessive current indicates mechanical binding or motor issues.

    Take current readings on energized circuits with proper PPE

  4. 4

    Inspect Conveyor Mechanism

    Check for chips jamming the conveyor, damaged conveyor belt, or seized conveyor drive components causing excessive motor load.

    Remove accumulated chips and lubricate conveyor drive points per maintenance schedule

DIY Feasiblehigh confidence

Call a technician if:

  • ·I/O board replacement required
  • ·Motor replacement beyond operator capability
  • ·Electrical troubleshooting reveals complex wiring issues

Prevention

  • Regular conveyor cleaning to prevent chip buildup
  • Monthly inspection of motor connections and overload settings
  • Lubricate conveyor drive components per maintenance schedule
  • Monitor motor current draw during operation

Common Mistakes

  • Ignoring thermal overload trips without finding root cause
  • Bypassing overload protection
  • Using incorrect fuse amperage ratings
  • Failing to check for chip jams before motor troubleshooting

Related Alarms

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free