Haas Alarm 1322 - Chip Conveyor Motor
Alarm 1322 fires when the Haas NGC control detects the chip conveyor motor has failed to start within the expected timeframe, has tripped its thermal overload protection, or the control hasn't received proper run confirmation from the conveyor motor relay feedback circuit. This alarm is triggered by the control monitoring the conveyor motor status through dedicated I/O points and current sensing circuits.
Haas Alarm 1322 - Chip Conveyor Motor
Chip Conveyor Motor
This alarm indicates the chip conveyor motor has faulted or the motor overload protection has tripped. The MOCON board monitors the chip conveyor motor circuit through either a thermal overload relay or a motor status input and triggers this alarm when a fault condition is detected. The conveyor will stop operation but the machine can continue to run, though chip buildup may become an issue during extended operation.
Root Cause Summary
Alarm 1322 fires when the Haas NGC control detects the chip conveyor motor has failed to start within the expected timeframe, has tripped its thermal overload protection, or the control hasn't received proper run confirmation from the conveyor motor relay feedback circuit. This alarm is triggered by the control monitoring the conveyor motor status through dedicated I/O points and current sensing circuits.
Safety
Causes and Fixes
Check Motor Overload Status
Navigate to CURRENT COMMANDS > I/O and check the conveyor motor overload input status. Look for the conveyor thermal overload bit to be active.
Ensure main power is locked out before accessing electrical components
Reset Motor Overload
Locate the conveyor motor starter in the electrical cabinet and manually reset the thermal overload relay by pressing the reset button on the motor starter.
Allow 10-15 minutes cooling time before resetting if motor is hot to touch
Check Motor Current Draw
Use a clamp meter to measure motor current during operation. Compare against nameplate amperage - excessive current indicates mechanical binding or motor issues.
Take current readings on energized circuits with proper PPE
Inspect Conveyor Mechanism
Check for chips jamming the conveyor, damaged conveyor belt, or seized conveyor drive components causing excessive motor load.
Remove accumulated chips and lubricate conveyor drive points per maintenance schedule
Call a technician if: