Haas codes
HaasServo/AxisIntermediate20-45 minutes

1002

Haas Alarm 1002 - Rotary Table Error

Rotary Table

This alarm indicates the rotary table on a 4-axis or 5-axis Haas machine has failed a position check, homing sequence, or enable signal verification. The MOCON board communicates with the rotary servo amplifier and monitors encoder feedback to ensure proper rotary axis positioning and operation. The machine will not allow cycle start or rotary motion until this fault is cleared and the axis is properly referenced.

Root Cause Summary

Haas alarm 1002 indicates a fault with the rotary table (4th axis) servo system, typically triggered when the rotary axis cannot reach commanded position within tolerance or experiences excessive following error. This alarm fires when the NGC control detects mechanical binding, servo drive faults, or encoder feedback issues on the A-axis rotary table.

Safety

  • 4th axis affected

Causes and Fixes

  1. 1

    Power down and inspect table

    Turn off machine power and manually rotate the table to check for binding, chips, or workpiece interference.

    Ensure machine is fully powered down and locked out before manual inspection

  2. 2

    Clear obstructions

    Remove any chips, coolant buildup, or workpiece clamps that may be interfering with table rotation.

    Check underneath the table where chips commonly accumulate

  3. 3

    Check table mounting

    Verify rotary table is properly secured to machine table and all mounting bolts are tight.

    Loose mounting can cause binding during rotation

  4. 4

    Test rotation

    Power up machine and test rotary table movement in JOG mode at slow feed rate to verify smooth operation.

DIY Feasiblemedium confidence

Call a technician if:

  • ·Servo drive shows internal fault codes
  • ·Encoder replacement needed
  • ·Servo tuning required
  • ·Electrical component replacement needed

Prevention

  • Regular chip clearing around rotary table
  • Periodic inspection of encoder cables
  • Proper workpiece clamping to avoid table overload
  • Regular lubrication per manufacturer schedule

Common Mistakes

  • Ignoring mechanical binding and only focusing on electrical causes
  • Adjusting servo parameters without understanding the root cause
  • Not checking for chip buildup in table mechanism
  • Forcing table movement when alarm is active

Related Alarms

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.