Haas Controller
System · Intermediate · 15-30 minutes
Haas Alarm 1005 - Probe Error
Alarm 1005 occurs when the Haas NGC control loses communication with the probe system or receives invalid probe signals during G31 probing cycles. This typically results from wireless interference, low battery voltage, probe receiver issues, or incorrect probe parameter settings in the control.
Haas Alarm 1005 - Probe Error
Probe
This alarm is triggered when the probe signal is activated or interrupted unexpectedly during non-probing operations, or when the probe fails to trigger during an active probing cycle. The MOCON board monitors the probe input through a dedicated digital input and expects the signal state to match the commanded operation. This alarm halts all axis motion immediately to prevent potential collision or incorrect measurement data from being recorded into work offsets.
Root Cause Summary
Alarm 1005 occurs when the Haas NGC control loses communication with the probe system or receives invalid probe signals during G31 probing cycles. This typically results from wireless interference, low battery voltage, probe receiver issues, or incorrect probe parameter settings in the control.
Safety
Causes and Fixes
Check Battery Status
Press CURRENT COMMANDS, then PROBING to access probe status screen. Check battery voltage indicator - should show green/good status.
Battery voltage below 2.4V typically causes intermittent communication issues before complete failure.
Replace Probe Battery
Remove probe from spindle, unscrew battery cap, and replace with new 3V lithium battery (CR2032 or equivalent per probe manufacturer specs).
Always power down spindle before removing probe to prevent accidental activation.
Test Communication
Install probe in spindle, navigate to MDI mode, and execute G31 Z-1.0 F10 to test probe trigger response and verify alarm clears.
Use a piece of paper to manually trigger probe during test - LED should illuminate on receiver when probe contacts paper.
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.