914

Fanuc Alarm 914 - DRAM PARITY: BYTE 2

SYSTEM ALARM 914

Fanuc alarm 914: SYSTEM ALARM 914. This alarm indicates a fault condition detected by the Fanuc control. Refer to the alarm number and name to identify the specific system or function involved.

Root Cause Summary

Fanuc Alarm 914 DRAM PARITY BYTE 2 indicates a hardware-level memory parity error in the second byte of the main CPU board's DRAM. This is a critical system alarm that typically points to failing or defective DRAM chips on the main PCB (CPU board) and requires hardware-level diagnostics and likely board replacement or repair.

Causes and Fixes

  1. 1

    Power off the CNC completely and wait 5 minutes. Remove and reseat the main CPU board in its slot to ensure proper connector contact. Check for any visible signs of corrosion, burn marks, or physical damage on the CPU board.

    Ensure proper ESD (electrostatic discharge) precautions before handling any PCBs. Use grounded wrist strap.

  2. 2

    Power on the system and observe if alarm 914 recurs immediately during boot sequence. Access SYSTEM > DIAGNOSIS and check diagnosis screen #800 (CNC system information) to verify system board recognition and any additional error codes.

  3. 3

    If alarm persists, document the control serial number and board part numbers. Contact Fanuc service to arrange main CPU board replacement or exchange repair. The board typically requires factory-level DRAM chip replacement.

    Main CPU board contains control-specific system parameters. Ensure full parameter backup exists before board replacement.

  4. 4

    After board replacement, reload all parameters from backup, verify parameter #3203 (serial number setting if applicable), and run a full axis movement test to confirm system integrity.

Service Recommendedmedium confidence

Call a technician if:

  • ·DRAM replacement required
  • ·PCB trace damage identified
  • ·Power supply replacement needed
  • ·Multiple alarm codes present

Prevention

  • Maintain clean electrical environment
  • Regular power supply voltage monitoring
  • Proper EMI shielding maintenance
  • Avoid temperature extremes in control cabinet

Common Mistakes

  • Mixing different DRAM specifications
  • Ignoring power supply ripple measurements
  • Poor ESD handling procedures
  • Attempting to repair PCB traces without proper equipment

Related Alarms

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.