FANUC codes
FANUCSystemIntermediate30-60 minutes

915

Fanuc Alarm 915 - DRAM PARITY: BYTE 3

SYSTEM ALARM 915

Fanuc alarm 915: SYSTEM ALARM 915. This alarm indicates a fault condition detected by the Fanuc control. Refer to the alarm number and name to identify the specific system or function involved.

Root Cause Summary

Alarm 915 DRAM PARITY: BYTE 3 indicates a hardware-level memory error in the main CPU board's DRAM chip responsible for byte 3 data storage. This is typically caused by a defective DRAM chip, failing CPU board, or less commonly, loose board connections or electrical noise affecting memory integrity.

Causes and Fixes

  1. 1

    Power down the CNC completely and discharge residual power by waiting 5 minutes. Reseat the main CPU board in the backplane, ensuring proper seating and connector integrity.

    Follow proper ESD precautions. Disconnect all power sources before opening control cabinet.

  2. 2

    Power up and observe if alarm recurs immediately during POST (Power-On Self Test). If alarm returns within seconds of boot, memory hardware is defective.

  3. 3

    Check FANUC board part number on main CPU board (locations vary: 0i uses A20B-8200-series, 16i/18i use A20B-8100-series, 30i/31i/32i use A20B-8101-series or later). Document full board number including suffix for replacement.

  4. 4

    Replace main CPU board with exact or compatible part number. After replacement, perform battery backup check and restore machine parameters from backup using SYSTEM > PMC > I/O or memory card restore function.

    Battery-backed SRAM will lose parameters during board replacement. Ensure complete parameter backup exists before proceeding.

Service Recommendedmedium confidence

Call a technician if:

  • ·CPU board replacement required
  • ·Power supply repair needed
  • ·Backplane replacement necessary

Prevention

  • Regular power supply voltage monitoring
  • Maintain proper EMC practices
  • Annual electrical connection inspection
  • UPS installation for clean power

Common Mistakes

  • Ignoring intermittent occurrences
  • Not checking power quality first
  • Attempting individual DRAM chip replacement
  • Operating with damaged cable shielding

Related Alarms

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.