Fanuc Alarm 915 - DRAM PARITY: BYTE 3
Alarm 915 DRAM PARITY: BYTE 3 indicates a hardware-level memory error in the main CPU board's DRAM chip responsible for byte 3 data storage. This is typically caused by a defective DRAM chip, failing CPU board, or less commonly, loose board connections or electrical noise affecting memory integrity.
Fanuc Alarm 915 - DRAM PARITY: BYTE 3
SYSTEM ALARM 915
Fanuc alarm 915: SYSTEM ALARM 915. This alarm indicates a fault condition detected by the Fanuc control. Refer to the alarm number and name to identify the specific system or function involved.
Root Cause Summary
Alarm 915 DRAM PARITY: BYTE 3 indicates a hardware-level memory error in the main CPU board's DRAM chip responsible for byte 3 data storage. This is typically caused by a defective DRAM chip, failing CPU board, or less commonly, loose board connections or electrical noise affecting memory integrity.
Causes and Fixes
Power down the CNC completely and discharge residual power by waiting 5 minutes. Reseat the main CPU board in the backplane, ensuring proper seating and connector integrity.
Follow proper ESD precautions. Disconnect all power sources before opening control cabinet.
Power up and observe if alarm recurs immediately during POST (Power-On Self Test). If alarm returns within seconds of boot, memory hardware is defective.
Check FANUC board part number on main CPU board (locations vary: 0i uses A20B-8200-series, 16i/18i use A20B-8100-series, 30i/31i/32i use A20B-8101-series or later). Document full board number including suffix for replacement.
Replace main CPU board with exact or compatible part number. After replacement, perform battery backup check and restore machine parameters from backup using SYSTEM > PMC > I/O or memory card restore function.
Battery-backed SRAM will lose parameters during board replacement. Ensure complete parameter backup exists before proceeding.
Call a technician if:
Prevention