Fanuc Alarm 918 - DRAM PARITY: BYTE 6
Fanuc Alarm 918 DRAM PARITY BYTE 6 indicates a hardware-level memory failure on the main CPU board, specifically in the sixth byte of the DRAM memory array. This is a critical hardware fault that typically requires main CPU board replacement, as the DRAM is soldered directly to the board and cannot be individually replaced.
Fanuc Alarm 918 - DRAM PARITY: BYTE 6
SYSTEM ALARM 918
Fanuc alarm 918: SYSTEM ALARM 918. This alarm indicates a fault condition detected by the Fanuc control. Refer to the alarm number and name to identify the specific system or function involved.
Root Cause Summary
Fanuc Alarm 918 DRAM PARITY BYTE 6 indicates a hardware-level memory failure on the main CPU board, specifically in the sixth byte of the DRAM memory array. This is a critical hardware fault that typically requires main CPU board replacement, as the DRAM is soldered directly to the board and cannot be individually replaced.
Causes and Fixes
Power cycle the CNC completely - turn OFF main breaker, wait 60 seconds, then power ON. If alarm clears temporarily but returns, this confirms intermittent DRAM failure requiring board replacement.
Back up all CNC parameters, programs, and offset data to memory card or via RS232 before proceeding, as board replacement will require data restoration.
Check SYSTEM > ALARM log to determine if alarm 918 is recurring or isolated. Note exact time stamps and any pattern (power-on only, random during operation, or after specific operations).
Verify main CPU board part number and serial number. For 0i series: typically A20B-8100-xxxx or A20B-8200-xxxx. For 30i/31i/32i series: A20B-8100-xxxx, A20B-8101-xxxx, or A02B-0319-xxxx depending on model.
Replace main CPU board with correct revision matched to current control software version. After installation, reload all backed-up parameters and perform full system initialization per Fanuc maintenance manual procedures.
Ensure replacement board firmware/software version matches or is compatible with current system. Version mismatch can cause additional alarms or system instability.
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.