FANUC codes
FANUCSystemIntermediate30-60 minutes

917

Fanuc Alarm 917 - DRAM PARITY: BYTE 5

SYSTEM ALARM 917

Fanuc alarm 917: SYSTEM ALARM 917. This alarm indicates a fault condition detected by the Fanuc control. Refer to the alarm number and name to identify the specific system or function involved.

Root Cause Summary

Fanuc Alarm 917 DRAM PARITY BYTE 5 indicates a hardware failure in the main CPU board's dynamic RAM, specifically in byte 5 of the memory array. This is a critical hardware fault caused by defective DRAM chips, memory corruption, or poor electrical connections on the main CPU PCB that requires board-level repair or replacement.

Causes and Fixes

  1. 1

    Power down the CNC completely and discharge residual power by waiting 5 minutes. Open the control cabinet and locate the main CPU board (typically labeled as CPU BOARD or MAIN BOARD with designation such as A20B-8100-series or A20B-8200-series depending on control model).

    Always follow LOTO procedures and verify zero voltage before touching internal components.

  2. 2

    Inspect the CPU board for physical damage, burn marks, corrosion, or swollen components around the DRAM chip area. Check all board-to-backplane connectors for proper seating and oxidation on contacts.

  3. 3

    If visual inspection shows no obvious damage, reseat the main CPU board by removing and reinstalling into the backplane connector. Ensure proper seating with even pressure on both ends of the board edge connector.

  4. 4

    Power up and observe if alarm clears. If alarm persists, the main CPU board requires replacement or factory repair service. Contact Fanuc service to order replacement board with matching control software version, or arrange board exchange/repair.

    Backup all programs, parameters, and PMC ladder using SYSTEM > MAINTENANCE > BACKUP or memory card before replacing CPU board.

Service Recommendedmedium confidence

Call a technician if:

  • ·Memory module replacement required
  • ·Power supply voltage issues detected
  • ·CPU board replacement needed
  • ·Advanced diagnostic equipment required

Prevention

  • Maintain stable power supply voltages
  • Ensure proper EMI shielding and grounding
  • Keep control cabinet clean and well-ventilated
  • Perform regular memory diagnostic tests
  • Monitor system for intermittent alarms

Common Mistakes

  • Using non-Fanuc approved memory modules
  • Ignoring power supply voltage tolerances
  • Poor ESD handling during board service
  • Inadequate cable shielding installation
  • Failing to backup data before hardware replacement

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.