FANUC codes
FANUCSystemIntermediate30-60 minutes

916

Fanuc Alarm 916 - DRAM PARITY: BYTE 4

SYSTEM ALARM 916

Fanuc alarm 916: SYSTEM ALARM 916. This alarm indicates a fault condition detected by the Fanuc control. Refer to the alarm number and name to identify the specific system or function involved.

Root Cause Summary

Alarm 916 DRAM PARITY: BYTE 4 indicates a hardware failure in the main CPU board's dynamic RAM memory module, specifically in byte 4 of the memory array. This is a critical hardware fault caused by defective DRAM chips, poor solder joints, or electrical noise affecting memory integrity on the main PCB.

Causes and Fixes

  1. 1

    Power down the CNC completely and wait 5 minutes. Remove all axis motor power cables and I/O connections to eliminate external noise sources. Reseat the main CPU board in its slot ensuring proper connector engagement.

    Ensure proper ESD grounding procedures before handling CPU board. Disconnect all power sources including battery backup.

  2. 2

    Power up and observe if alarm recurs immediately during boot sequence. If alarm persists before reaching System screen, the DRAM hardware is confirmed defective.

  3. 3

    Access MAINTENANCE > SYSTEM > PMC MEMORY or DIAGNOSIS screen to check for additional memory-related alarms (915, 917, 918 series). Document all displayed errors for Fanuc service.

  4. 4

    Replace the main CPU board assembly with a compatible spare. After installation, initialize parameters from backup using SYSTEM > I/O CHANNEL and restore all parameter sets (000-9999), PMC ladder, and macro programs.

    Replacing CPU board requires system reinitialization. Ensure complete parameter backup exists before proceeding. Board must match control series and software version.

Service Recommendedhigh confidence

Call a technician if:

  • ·Alarm persists after power cycling
  • ·Multiple memory-related alarms occur
  • ·System parameters become corrupted
  • ·CPU board replacement required

Prevention

  • Maintain proper cabinet temperature and ventilation
  • Ensure stable power supply voltages
  • Implement proper EMI shielding and grounding
  • Regular backup of system parameters and programs

Common Mistakes

  • Ignoring intermittent occurrences hoping they resolve
  • Not backing up data before troubleshooting
  • Attempting to repair CPU board components
  • Overlooking power supply issues as root cause

Related Alarms

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.