Fanuc Alarm 913 - DRAM PARITY: BYTE 1
Alarm 913 DRAM PARITY: BYTE 1 indicates a hardware failure in the main CPU board's dynamic RAM (DRAM) memory chip responsible for byte 1 data storage. This is a critical hardware fault caused by defective DRAM chips, loose board connections, or electrical damage to the main PCB. The parity check circuit has detected data corruption in the memory subsystem.
Fanuc Alarm 913 - DRAM PARITY: BYTE 1
SYSTEM ALARM 913
Fanuc alarm 913: SYSTEM ALARM 913. This alarm indicates a fault condition detected by the Fanuc control. Refer to the alarm number and name to identify the specific system or function involved.
Root Cause Summary
Alarm 913 DRAM PARITY: BYTE 1 indicates a hardware failure in the main CPU board's dynamic RAM (DRAM) memory chip responsible for byte 1 data storage. This is a critical hardware fault caused by defective DRAM chips, loose board connections, or electrical damage to the main PCB. The parity check circuit has detected data corruption in the memory subsystem.
Causes and Fixes
Power OFF the CNC completely. Wait 30 seconds, then power ON to clear transient memory states and verify if alarm persists immediately after boot.
If alarm reappears immediately on every power cycle, main CPU board replacement is required.
Access SYSTEM > MAINTENANCE > BOARD CHECK screen to view hardware diagnostic results. Record any additional error codes or memory test failures displayed.
Contact Fanuc service for main CPU board replacement. Provide control model (0i-MD, 31i-B5, etc.) and full serial number from SYSTEM > CNC ID screen for correct board identification.
DRAM is soldered to main board - individual chip replacement requires factory-level BGA rework and is not field-serviceable.
Before board replacement, backup all parameters using SYSTEM > PMC > I/O and parameter backup functions. Use CF card or memory card to save ladder, parameters, and macro programs.
All data will be lost during main board replacement - complete system backup is mandatory.
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.