Fanuc Alarm 911 - SRAM PARITY: BYTE 1
Fanuc Alarm 911 SRAM PARITY BYTE 1 indicates a parity error in the first byte of the Static RAM module where critical system data, parameters, and programs are stored. This typically results from low or depleted backup battery voltage, corrupted SRAM module, or physical damage to the memory circuit on the main PCB.
Fanuc Alarm 911 - SRAM PARITY: BYTE 1
DRAM Parity
Fanuc program alarm 911: DRAM Parity. The part program contains an error or illegal condition that the Fanuc control cannot execute. Correct the program to clear this alarm.
Root Cause Summary
Fanuc Alarm 911 SRAM PARITY BYTE 1 indicates a parity error in the first byte of the Static RAM module where critical system data, parameters, and programs are stored. This typically results from low or depleted backup battery voltage, corrupted SRAM module, or physical damage to the memory circuit on the main PCB.
Safety
Causes and Fixes
Check battery voltage at SYSTEM > MAINTENANCE > BATTERY screen. Voltage should read 3.0-3.6V for lithium batteries. If below 2.7V, immediate replacement is required.
Do not remove the old battery until the new battery is connected or all parameters and programs will be lost. Use hot-swap procedure with main power ON.
Physically measure battery voltage with multimeter at the battery connector on the main PCB (CPU board). Verify connector terminals are clean and making proper contact.
After battery replacement, clear the alarm and perform SRAM initialization: Set Parameter 0 (diagnostic parameter) bit 7 to 1, cycle power, then restore parameters from backup. Set Parameter 3202#0=1 to enable parameter write.
SRAM initialization erases all parameters, offsets, and programs. Ensure you have a complete backup before proceeding.
Verify alarm clears by cycling power (full power-down for 10 seconds). Check SYSTEM > ALARM > ALARM HISTORY to confirm no recurrence of alarm 911.
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.