Fanuc Alarm 602 - n AXIS: INV. OVERHEAT
Fanuc alarm 602 (INV. OVERHEAT) indicates the servo amplifier (inverter module) has exceeded its thermal threshold, typically 85-95°C depending on amplifier model. The alarm is triggered by internal thermistors in the power module that monitor IGBT/IPM temperature. This is a protective shutdown to prevent permanent damage to the servo drive components.
Fanuc Alarm 602 - n AXIS: INV. OVERHEAT
SERVO ALARM 602
The servo amplifier has overheated. Check cooling fan, air filter, ambient temperature, and duty cycle.
Root Cause Summary
Fanuc alarm 602 (INV. OVERHEAT) indicates the servo amplifier (inverter module) has exceeded its thermal threshold, typically 85-95°C depending on amplifier model. The alarm is triggered by internal thermistors in the power module that monitor IGBT/IPM temperature. This is a protective shutdown to prevent permanent damage to the servo drive components.
Causes and Fixes
Check amplifier cooling fan operation. With power on (alarm present), verify fan rotation visually and audibly. For αi/βi servo amplifiers, fan failure often coincides with alarm 602. Replace fan if not operating (typical part: A860-0104-Txxx series).
Ensure proper lockout/tagout before opening cabinet. High voltage present at amplifier terminals.
Inspect and clean/replace cabinet air filters. Check intake and exhaust filters for dust accumulation. Clogged filters reduce airflow by 50% or more, causing thermal buildup even with functional fans.
Verify ambient temperature around servo amplifier. Check DIAGNOSIS screen > SERVO > temperature monitoring (parameters 1611-1614 on 0i/30i/31i systems show servo amp temperature). Ambient should be ≤40°C (104°F) per Fanuc specifications. Use infrared thermometer to measure cabinet internal temperature.
Ensure minimum clearance around amplifier: 100mm (4 inches) above/below for ventilation per Fanuc installation manual. Check for adjacent heat sources (transformers, other amplifiers) that raise local ambient temperature.
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.