axismd.ai
FANUC Controller
Program/G-code · Intermediate · 15-30 minutes
Fanuc Alarm 175 - ILLEGAL G07.1 AXIS
Alarm 175 occurs when the G07.1 (Cylindrical Interpolation) command contains an improperly specified axis or multiple axes in the activation block. The CNC requires only a single rotary axis to be designated as the cylindrical axis, and linear axes X, Y, Z must be capable of coordinated movement with it according to parameter settings.
Fanuc Alarm 175 - ILLEGAL G07.1 AXIS
Circular Interpolation Plane Error
An axis which cannot perform cylindrical interpolation was specified, or more than one axis was specified in a G07.1 block.
Root Cause Summary
Alarm 175 occurs when the G07.1 (Cylindrical Interpolation) command contains an improperly specified axis or multiple axes in the activation block. The CNC requires only a single rotary axis to be designated as the cylindrical axis, and linear axes X, Y, Z must be capable of coordinated movement with it according to parameter settings.
Safety
Causes and Fixes
Review the program line containing G07.1. Correct format is 'G07.1 C_' where C is the rotary axis. Remove any additional axis specifications (X, Y, Z, or additional rotary axes) from this block.
Verify parameter 1022 bit 5 (CYL) is set to 1 to enable cylindrical interpolation function. Access via SYSTEM > PARAM > [1022] and check bit configuration.
Confirm the specified rotary axis matches the axis designated in parameter 1025 (Cylindrical Interpolation Axis Number). Common setting is 3 for C-axis on mill-turn machines.
Test with simplified G07.1 block specifying only the single rotary axis, followed by G07.1 IP0 (cancel) to verify proper modal activation.
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.