axismd.ai
FANUC Controller
Program/G-code · Basic · 15-30 minutes
Fanuc Alarm 152 - OVER MAXIMUM TOOL NUMBER
Fanuc Alarm 152 occurs when the number of tools registered in a single tool group exceeds the maximum allowable tool registration number defined by system parameters. This is typically caused by attempting to register too many tools in a magazine group, incorrect tool group parameter settings, or magazine configuration mismatches in the tool management system.
Fanuc Alarm 152 - OVER MAXIMUM TOOL NUMBER
Illegal G Code
The number of tools registered in one group exceeded the maximum allowable tool registration number.
Root Cause Summary
Fanuc Alarm 152 occurs when the number of tools registered in a single tool group exceeds the maximum allowable tool registration number defined by system parameters. This is typically caused by attempting to register too many tools in a magazine group, incorrect tool group parameter settings, or magazine configuration mismatches in the tool management system.
Safety
Causes and Fixes
Navigate to SYSTEM > PARAM and check parameter 13220 (maximum tool registration number per group). Verify this value matches your magazine configuration and has not been inadvertently reduced.
Check parameters 13201-13204 (number of tools in magazine 1-4). Confirm the total tool count being registered does not exceed the capacity defined for the specific magazine group being used.
Access OFFSET SETTING > TOOL MANAGEMENT screen or MDI mode and review the current tool registration table. Count the number of tools assigned to the group triggering the alarm.
Delete unnecessary tool registrations from the group or redistribute tools across multiple groups if available. Alternatively, increase parameter 13220 if the physical magazine supports more tools and machine specifications allow.
Parameter 13220 must not exceed the physical magazine capacity or system maximum tool limit defined in parameter 13200.
Call a technician if:
Prevention
Common Mistakes