axismd.ai
FANUC Controller
Program/G-code · Intermediate · 15-30 minutes
Fanuc Alarm 151 - GROUP NOT FOUND AT LIFE DATA
Fanuc Alarm 151 occurs when the G-code program references a tool group number in a T-code or tool life management command (G10 L3) that does not exist in the tool life management data table. This is typically caused by incorrect tool group registration, program error referencing non-existent groups, or corrupted tool life data.
Fanuc Alarm 151 - GROUP NOT FOUND AT LIFE DATA
Canned Cycle Error
Fanuc program alarm 151: Canned Cycle Error. The part program contains an error or illegal condition that the Fanuc control cannot execute. Correct the program to clear this alarm.
Root Cause Summary
Fanuc Alarm 151 occurs when the G-code program references a tool group number in a T-code or tool life management command (G10 L3) that does not exist in the tool life management data table. This is typically caused by incorrect tool group registration, program error referencing non-existent groups, or corrupted tool life data.
Safety
Causes and Fixes
Press OFFSET/SETTING key, then select the LIFE soft key to access tool life management screen. Verify if the tool group number referenced in the program exists in the registered groups list.
If group is missing, register the tool group: Press soft key [OPR] > [SET GRP] or use G10 L3 command to define the group. Input group number, tool count, and life type (time/count). Example: G10 L3 P1 R5 L10000; (Group 1, 5 tools, 10000 count life).
Check parameter 6800#0 (TLF) = 1 to confirm tool life management function is enabled. Navigate to SYSTEM > PARAM > [6800] and verify bit 0 is set to 1.
Parameter write enable switch (parameter 3202#0=1 or KEY switch to EDIT) must be active to modify parameters.
After registering tool group, reset alarm with RESET key and restart program. Verify tool life data is retained by checking OFFSET > LIFE screen shows all registered groups.
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.