Fanuc Alarm 067 - CAN NOT ERROR IN MDI MODE

SYSTEM ALARM 67

Fanuc alarm 067: SYSTEM ALARM 67. This alarm indicates a fault condition detected by the Fanuc control. Refer to the alarm number and name to identify the specific system or function involved.

Root Cause Summary

Alarm 067 occurs when a multiple repetitive canned cycle command (G70, G71, G72, or G73) is executed in MDI mode, but the program block that defines the cutting sequence is not stored in the CNC's program memory area. These cycles require a registered program sequence in memory to reference and repeat, which cannot be provided when commanded directly through MDI input.

Causes and Fixes

  1. 1

    Verify the G-code being entered in MDI mode. Check if G70 (finish cycle), G71 (turning roughing), G72 (facing roughing), or G73 (pattern repeating) is being commanded.

  2. 2

    Register the complete cycle program including the G70-G73 command and associated cutting sequence blocks into program memory (O-number program). Use EDIT mode to input or transfer the program via RS-232 or Ethernet.

  3. 3

    Execute the program containing the multiple repetitive cycle from MEMORY or AUTO mode instead of MDI mode. Select the O-number program and run from the beginning or use block search to the desired line.

  4. 4

    If testing individual moves is required, execute only the geometry definition blocks (non-cycle commands) in MDI mode, or use single block execution in MEMORY mode for the complete program.

DIY Feasiblehigh confidence

Call a technician if:

  • ·Parameter corruption suspected
  • ·Memory hardware issues
  • ·Persistent alarm after program verification

Prevention

  • Always verify program exists before using G70-G73
  • Use consistent sequence numbering
  • Regularly backup programs
  • Document P and Q address ranges

Common Mistakes

  • Using non-existent sequence numbers
  • Forgetting to load reference programs
  • Mixing up P and Q address order
  • Attempting complex canned cycles in MDI without proper setup

Related Alarms

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.