Fanuc Alarm 071 - Searched Data Not Found

Data Not Found

Fanuc program alarm 071: Data Not Found. The part program contains an error or illegal condition that the Fanuc control cannot execute. Correct the program to clear this alarm.

Root Cause Summary

Fanuc Alarm 071 occurs when the CNC control system cannot locate specified data during a memory search operation. This typically happens when a program attempts to search for a program number, sequence number (N-code), or P-address that does not exist in the current memory or active program. The alarm is triggered by unsuccessful execution of search commands or G-code blocks referencing non-existent data.

Safety

  • Search cannot complete

Causes and Fixes

  1. 1

    Navigate to EDIT mode and press PROG key. Verify the exact program number being called matches an existing program in memory. Check the calling block syntax (M98 P____ or G65 P____) against available programs.

  2. 2

    Press SYSTEM > PROGRAM > DIR LIST or use the program directory function to display all programs stored in memory. Confirm the target O-number exists and is not corrupted.

  3. 3

    If using external device call (parameter 3107 bit 0=1), verify the program exists on the USB/CF card or network drive. Check parameter 3107 (external device setup) and parameters 20-22 (I/O channel settings) are correctly configured.

  4. 4

    Review parameters 3201-3204 (program number range restrictions) to ensure the called program number is within allowed ranges. Re-register or transfer the missing program from backup media if necessary.

    Ensure parameter write enable switch (PWE) is ON if modifying program restrictions or I/O parameters.

DIY Feasiblehigh confidence

Call a technician if:

  • ·Memory hardware failure suspected
  • ·Parameter corruption across multiple settings
  • ·Persistent alarm after all software troubleshooting

Prevention

  • Maintain organized program numbering system
  • Regular backup of programs and parameters
  • Use consistent sequence numbering in programs
  • Verify program syntax before loading

Common Mistakes

  • Confusing program numbers with sequence numbers
  • Not checking for leading zeros in program calls
  • Forgetting to enable custom macro parameter 6050
  • Removing storage devices during operation

Related Alarms

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.