Siemens 27006 - Axis Test ext. pulse deletion running

Axis Test ext. pulse deletion running

Siemens SINUMERIK alarm 27006: Axis Test ext. pulse deletion running. Detailed remedy is being verified against the current Siemens diagnostics manual.

Root Cause Summary

SINUMERIK alarm 27006 occurs when the Single Block (SBL) execution mode is intentionally or unintentionally activated, causing the NCK to pause after each NC block execution. This alarm serves as a status notification that continuous automatic program execution is disabled and operator intervention is required to advance through each program step.

Safety

  • Only qualified personnel should diagnose and clear control alarms; follow the machine builder's safety procedures and lockout/tagout where hardware work is required.

Causes and Fixes

  1. 1

    Check MCP Single Block Key Status

    Examine the machine control panel for illuminated SBL key or check HMI Operating Area > Machine > Operating Mode display for active Single Block indicator.

    On OP015T/OP019, the SBL key has an integrated LED that illuminates when active.

  2. 2

    Verify HMI Single Block Setting

    Navigate to HMI > Machine > Operating Modes and check if 'Single Block' checkbox is selected in the execution options.

    The SBL mode can be toggled via softkey SK4 'Single Block' in most SINUMERIK HMI versions.

  3. 3

    Deactivate Single Block Mode

    Press the SBL key again to deactivate or uncheck Single Block option in HMI to clear DB21.DBX1.4 signal and resume continuous execution.

    Ensure program position and workpiece setup are correct before resuming automatic mode.

DIY Feasiblehigh confidence

Call a technician if:

  • ·PLC logic modifications required
  • ·Machine data parameter changes needed
  • ·Persistent HMI communication errors

Prevention

  • Train operators on proper SBL key usage
  • Document machine-specific restart procedures
  • Regular HMI-NCK communication diagnostics
  • Review PLC safety logic during preventive maintenance

Common Mistakes

  • Attempting to run automatic cycle without clearing SBL mode
  • Ignoring underlying safety conditions that triggered automatic SBL
  • Modifying machine data without understanding restart behavior impact
  • Bypassing PLC safety interlocks instead of resolving root cause