Siemens SINUMERIK codes
Siemens SINUMERIKSystemIntermediate10-20 minutes

27020

Siemens 27020 - Axis stop E triggered

Axis stop E triggered

This alarm is output together with alarms 27011 "Safe velocity exceeded" or 27012 "Safe limit position exceeded" (when configured as such in MD $MA_SAFE_VELO_STOP_MODE, $MA_SAFE_VELO_STOP_REACTION or MD: $MA_SAFE_POS_STOP_MODE) Control reaction: NC Start disable in this channel. Interface signals are set. Alarm display. NC Stop on alarm. Trigger a LIFTFAST ASUB and internal activation of the safe operational stop (SBH) after expiry of the time set in MD $MA_SAFE_STOP_SWITCH_TIME_E.

Root Cause Summary

Alarm 27020 occurs when an axis actual position exceeds the configured Safe Limited Position (SLP) boundaries defined in the Safety Integrated parameters. This safety function violation triggers immediate axis stop and requires safety-acknowledged reset through the safety PLC or HMI before motion can resume.

Safety

  • Safety Integrated alarm: work may only be carried out by qualified personnel. After any change to Safety Integrated settings or hardware, repeat the Safety Integrated acceptance test before returning the machine to service.

Causes and Fixes

  1. 1

    Check Current Axis Position

    Navigate to Diagnostics > Service > Axis States and verify actual position against configured SLP limits in Safety parameters.

    Use machine coordinate system values, not workpiece coordinates when checking SLP boundaries

  2. 2

    Verify SLP Parameter Settings

    Access Safety Integrated > SLP Configuration and check SLP_POS_MIN/SLP_POS_MAX parameters for the affected axis.

    SLP parameter changes require safety validation and may need TÜV certification

  3. 3

    Perform Safety Reset

    Execute safety-acknowledged reset via F-PLC or safety HMI, then manually jog axis back within SLP window before resuming automatic operation.

DIY Feasiblehigh confidence

Call a technician if:

  • ·SLP parameter modification required beyond operator authority
  • ·Encoder feedback system malfunction
  • ·Safety PLC programming changes needed

Prevention

  • Regularly verify SLP window settings match operational requirements
  • Include SLP status in pre-operation safety checklist
  • Train operators on proper SLP activation/deactivation procedures

Common Mistakes

  • Attempting motion reset without safety acknowledgment
  • Modifying SLP parameters without proper safety validation
  • Ignoring reference point validity before SLP operation

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?