axismd.ai
Siemens SINUMERIK Controller
Servo/Axis · Intermediate · 30-120 minutes
Siemens 840D 27022 - Axis stop C triggered
Alarm 27022 is a secondary alarm triggered when axis safety functions detect a fault condition (Safe Velocity Exceeded or Safe Position Limit Exceeded) and the configured stop reaction is set to 'Stop C' (monitored stop). This alarm indicates the safety-monitored deceleration to standstill was initiated, but the axis did not achieve safe velocity compliance within the monitored parameters defined in $MA_SAFE_VELO_STOP_MODE or $MA_SAFE_POS_STOP_MODE.
Siemens 840D 27022 - Axis stop C triggered
Axis stop C triggered
Siemens SINUMERIK alarm 27022: Axis stop C triggered. This alarm indicates a fault or error condition on the SINUMERIK 840D control. Refer to the Siemens SINUMERIK alarm documentation for the complete description and remedy.
Root Cause Summary
Alarm 27022 is a secondary alarm triggered when axis safety functions detect a fault condition (Safe Velocity Exceeded or Safe Position Limit Exceeded) and the configured stop reaction is set to 'Stop C' (monitored stop). This alarm indicates the safety-monitored deceleration to standstill was initiated, but the axis did not achieve safe velocity compliance within the monitored parameters defined in $MA_SAFE_VELO_STOP_MODE or $MA_SAFE_POS_STOP_MODE.
Safety
Causes and Fixes
Check NCK parameters: Display $MA_SAFE_VELO (safe velocity threshold) and $MA_SAFE_VELO_STOP_REACTION (should be 2 or 3 for Stop C). Navigate to Diagnostics > Parameters > Machine Data > Safety Functions.
Verify MD 32310 (MAX_AX_ACCEL) and MD 32300 (MAX_AX_VELO) are correctly set for the axis. Ensure deceleration ramp is sufficient to bring axis below safe velocity threshold within $MA_SAFE_VELO_STOP_TIME_LIMIT (typically 50-500ms).
Increasing MAX_AX_ACCEL beyond mechanical limits can cause servo instability. Consult machine tool documentation.
In Siemens HMI, navigate to Diagnostics > Alarms > Alarm log and check the preceding alarm (27011 'Safe velocity exceeded'). This confirms the root fault condition.
Clear alarm history and perform a controlled axis jog at reduced feedrate (10-25% of MAX_AX_VELO) to confirm axis responds to Stop C deceleration without oscillation or overshoot.
Perform this test in Manual mode with Machine Ready disabled until issue is confirmed resolved.
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.