Siemens 27010 - Axis tolerance for safe standstill exceeded
SIEMENS alarm 27010 'SLS Limit Exceeded' indicates that a Safety Integrated function has detected axis movement beyond configured Safe Limited Speed (SLS) parameters. This typically occurs when an axis exceeds the maximum allowed velocity or position limits defined in the safety configuration. The most common fix involves checking and adjusting SLS monitoring parameters in the safety configuration.
Siemens 27010 - Axis tolerance for safe standstill exceeded
Axis tolerance for safe standstill exceeded
Siemens SINUMERIK alarm 27010: Axis tolerance for safe standstill exceeded. Detailed remedy is being verified against the current Siemens diagnostics manual.
Root Cause Summary
SIEMENS alarm 27010 'SLS Limit Exceeded' indicates that a Safety Integrated function has detected axis movement beyond configured Safe Limited Speed (SLS) parameters. This typically occurs when an axis exceeds the maximum allowed velocity or position limits defined in the safety configuration. The most common fix involves checking and adjusting SLS monitoring parameters in the safety configuration.
Safety
Causes and Fixes
Check current SLS velocity settings
Navigate to Diagnostics > Safety Integrated > SLS Monitor to view current velocity limits and actual axis speeds when alarm occurred.
Compare the logged velocity at alarm time with the SLS limit - often the difference is minimal indicating a borderline condition
Review machine data parameters
Check MD36600 (SLS_VEL_LIMIT) for each affected axis to verify the configured maximum velocity matches machine capabilities and program requirements.
Modifying safety parameters requires proper authorization and may need safety validation
Verify feedrate override settings
Ensure feedrate override is not set above 100% when SLS limits are active, as this can cause programmed speeds to exceed safety limits.
SLS monitoring is active even during override conditions, unlike some other safety functions
Test with reduced rapid traverse rate
Temporarily reduce G00 rapid traverse rate in machine data MD32000 (MAX_AX_VELO) to confirm if velocity limiting resolves the alarm.
This is a diagnostic step - don't leave production speeds permanently reduced
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.