Siemens 27008 - Axis SW limit switch deactivated

Axis SW limit switch deactivated

Siemens SINUMERIK alarm 27008: Axis SW limit switch deactivated. Detailed remedy is being verified against the current Siemens diagnostics manual.

Root Cause Summary

SINUMERIK alarm 27008 indicates the block skip function is active, causing all program blocks prefixed with '/' to be skipped during execution. This is typically caused by the block skip switch being enabled on the machine control panel or through the HMI interface.

Safety

  • Spindle hazard: ensure the spindle is at standstill before working near it; follow lockout/tagout procedures.

Causes and Fixes

  1. 1

    Check Physical Switch Position

    Locate the 'BLOCK SKIP' or 'SKIP' switch on the machine control panel and verify its position. Toggle to OFF position if skipping is not desired.

    On older SINUMERIK systems, this switch may be labeled as 'SATZ UEBERG' in German installations.

  2. 2

    Verify Switch Functionality

    Toggle the switch ON/OFF while monitoring the HMI status display to confirm proper switch operation and signal transmission to NCK.

    Ensure machine is in safe state before testing switch functionality.

  3. 3

    Test Program Execution

    Run a test program containing optional blocks (/) to verify that block skip function responds correctly to switch position changes.

DIY Feasiblehigh confidence

Call a technician if:

  • ·PLC logic modifications required
  • ·Physical switch hardware failure
  • ·Custom machine builder functions involved

Prevention

  • Establish clear procedures for block skip usage
  • Train operators on proper switch operation
  • Document optional block usage in programs
  • Regular verification of control panel switch positions

Common Mistakes

  • Assuming alarm indicates malfunction when skip is intentionally active
  • Disabling skip without consulting production requirements
  • Overlooking HMI virtual control panel settings
  • Not checking program content for critical operations marked as optional

Related Alarms

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.