Siemens SINUMERIK codes
Siemens SINUMERIKSystemBasic2-5 minutes

27005

Siemens 27005 - Axis error in data cross check: static actual value difference

Axis error in data cross check: static actual value difference

Siemens SINUMERIK alarm 27005: Axis error in data cross check: static actual value difference. Detailed remedy is being verified against the current Siemens diagnostics manual.

Root Cause Summary

SIEMENS alarm 27005 'Dry Run Active' occurs when the NCK channel is operating in dry run mode, typically activated through operator panel selection, PLC interface signal DB21.DBX1.6, or NC parameter settings. This informational alarm indicates that programmed feed rates are overridden by the dry run feed rate and spindle/coolant outputs are disabled for safe program verification.

Safety

  • Only qualified personnel should diagnose and clear control alarms; follow the machine builder's safety procedures and lockout/tagout where hardware work is required.

Causes and Fixes

  1. 1

    Check HMI Operating Mode

    Navigate to the HMI main screen and verify the current operating mode display. Look for 'DRY RUN' or dry run symbol in the mode selection area.

    The dry run mode icon typically shows a crossed-out spindle symbol on SINUMERIK HMIs

  2. 2

    Access Mode Selection Menu

    Press the 'Mode' softkey or navigate to Machine > Operating Mode menu to access the mode selection screen.

    Ensure machine is in a safe state before changing operating modes

  3. 3

    Deactivate Dry Run Mode

    Select 'AUTO' or 'MDA' mode instead of 'DRY RUN' mode. The alarm should clear immediately when dry run mode is deselected.

  4. 4

    Verify Mode Change

    Confirm the operating mode has changed on the HMI display and that alarm 27005 is no longer active in the alarm buffer.

DIY Feasiblehigh confidence

Call a technician if:

  • ·PLC program modifications required
  • ·Safety system integration issues
  • ·Machine data corruption

Prevention

  • Train operators on proper mode selection
  • Document custom M-code functions
  • Regular safety system verification
  • Implement mode selection lockout procedures

Common Mistakes

  • Ignoring PLC interface signals
  • Modifying safety logic incorrectly
  • Not checking external selector switches
  • Assuming only HMI controls dry run mode

Related Alarms