Siemens 840D 100923 - Remote diagnostics: Connection aborted by remote PC
Alarm 100923 occurs when the remote diagnostics connection between the SINUMERIK 840D control and a remote PC is unexpectedly terminated from the PC side. This typically happens due to network issues, software problems on the remote PC, or intentional/unintentional disconnection during an active remote diagnostics session.
Siemens 840D 100923 - Remote diagnostics: Connection aborted by remote PC
Remote diagnostics: Connection aborted by remote PC
Siemens SINUMERIK operator message 100923: Remote diagnostics: Connection aborted by remote PC. This is an informational message from the SINUMERIK control indicating a system status or operation result that may require operator action.
Root Cause Summary
Alarm 100923 occurs when the remote diagnostics connection between the SINUMERIK 840D control and a remote PC is unexpectedly terminated from the PC side. This typically happens due to network issues, software problems on the remote PC, or intentional/unintentional disconnection during an active remote diagnostics session.
Safety
Causes and Fixes
Verify physical network cable connections at both the CNC control NCU and the remote PC. Check for loose or damaged RJ45 connectors and test cable continuity.
Test network connectivity using PING command from HMI or service laptop to verify bi-directional communication between CNC and remote PC IP addresses.
Check network switch and router status LEDs. Verify network infrastructure is operational and no IP conflicts exist on the subnet.
Review firewall settings on both CNC network and remote PC to ensure remote diagnostics ports (typically TCP 102, 8080, or custom ports) are not blocked or timing out.