Siemens SINUMERIK Controller
Communication · Intermediate · 30-120 minutes
Siemens 840D 100922 - Remote diagnostics: No connection by remote PC, timeout
Alarm 100922 indicates that a remote diagnostics connection attempt to the SINUMERIK 840D system has failed due to a timeout. This occurs when the remote PC cannot establish or maintain communication with the control within the expected time frame, typically due to network issues, firewall blocking, incorrect configuration, or the remote diagnostics service not being active on the control.
Siemens 840D 100922 - Remote diagnostics: No connection by remote PC, timeout
Remote diagnostics: No connection by remote PC, timeout
Siemens SINUMERIK alarm 100922: Remote diagnostics: No connection by remote PC, timeout. This alarm indicates a required configuration element, parameter, or program component is missing or has not been set up.
Root Cause Summary
Alarm 100922 indicates that a remote diagnostics connection attempt to the SINUMERIK 840D system has failed due to a timeout. This occurs when the remote PC cannot establish or maintain communication with the control within the expected time frame, typically due to network issues, firewall blocking, incorrect configuration, or the remote diagnostics service not being active on the control.
Safety
Causes and Fixes
Verify physical network connection: Check Ethernet cable connections at the NCU and network switch, ensure link LEDs are illuminated on both ends, and test cable integrity if necessary.
Confirm IP connectivity: From the HMI or service laptop connected locally, ping the gateway and remote PC IP address to verify basic network routing. Check IP address, subnet mask, and gateway settings in the NCU network configuration (Startup > Network).
Check firewall settings on both the control side and remote PC: Ensure TCP port 102 (S7 communication) and ports 443/4840 (for newer SINUMERIK Integrate connections) are open bidirectionally. Temporarily disable firewalls for testing if safe to do so in your environment.
Only disable firewalls temporarily for testing and ensure proper security policies are maintained in production environments.
Verify VPN or remote access connection: If using VPN, confirm the tunnel is established, check VPN client logs for errors, and verify routing tables allow traffic to the machine network subnet.