Siemens 840D 100930 - No other settings relevant if no ping server

No other settings relevant if no ping server

Siemens SINUMERIK alarm 100930: No other settings relevant if no ping server. This alarm indicates a required configuration element, parameter, or program component is missing or has not been set up.

Root Cause Summary

Alarm 100930 indicates a network configuration issue where ping server settings have been defined in the system, but other required network parameters are missing or incorrectly configured. This alarm typically occurs during HMI startup or network initialization when the system detects incomplete TCP/IP configuration despite ping server entries being present.

Safety

  • Refer to Siemens documentation
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Access HMI: Navigate to Startup → Service → Settings → Network/HMI Advanced settings menu.

  2. 2

    Check if ping server IP address is configured. Note the current network settings including IP address, subnet mask, gateway, and DNS servers.

  3. 3

    Either remove/clear the ping server entry if not needed, OR complete all network parameters (subnet mask, default gateway, DNS) to match your facility network requirements.

    Document original settings before making changes. Incorrect network settings can prevent HMI communication.

  4. 4

    Save configuration, perform NCK/HMI restart, and verify alarm clears and network connectivity functions properly.

Service Recommended confidence

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.