Siemens 840D 100935 - Remote diagnostics: No response from remote PC (timeout)

Remote diagnostics: No response from remote PC (timeout)

Siemens SINUMERIK alarm 100935: Remote diagnostics: No response from remote PC (timeout). This alarm indicates a required configuration element, parameter, or program component is missing or has not been set up.

Root Cause Summary

Alarm 100935 occurs when the CNC control attempts to establish or maintain a remote diagnostics connection with a remote PC but fails to receive a response within the configured timeout period. This typically indicates network connectivity issues, firewall blocking, incorrect configuration of the remote diagnostics service, or the remote PC application not running or responding properly.

Safety

  • Refer to Siemens documentation
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Verify physical network connection: Check Ethernet cable connection at both NCU and switch/router, ensure link LEDs are active and green.

  2. 2

    From HMI, navigate to Commissioning > Network > Configuration and verify the IP address, subnet mask, and gateway settings match your network topology.

  3. 3

    Ping the remote PC from the SINUMERIK control using the diagnostics network tools to confirm basic IP connectivity exists.

  4. 4

    Check network switch ports and VLAN configuration to ensure the CNC and remote PC are on the same network segment and can communicate.

Service Recommended confidence

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.