Siemens 840D 100934 - Remote diagnostics: Error 10 -SendFileToRemote
Alarm 100934 indicates a failure during remote file transfer from the SINUMERIK control to a remote diagnostics server or service PC. This error specifically relates to the SendFileToRemote() function failing, typically during a remote diagnostics session initiated via VPN, TeamViewer, or Siemens remote service connection. The %1 parameter provides additional context about the specific file or transfer error condition.
Siemens 840D 100934 - Remote diagnostics: Error 10 -SendFileToRemote
Remote diagnostics: Error 10 -SendFileToRemote
Siemens SINUMERIK alarm 100934: Remote diagnostics: Error 10 -SendFileToRemote-. This alarm indicates an error condition in the NC program or control configuration that must be resolved before the operation can continue.
Root Cause Summary
Alarm 100934 indicates a failure during remote file transfer from the SINUMERIK control to a remote diagnostics server or service PC. This error specifically relates to the SendFileToRemote() function failing, typically during a remote diagnostics session initiated via VPN, TeamViewer, or Siemens remote service connection. The %1 parameter provides additional context about the specific file or transfer error condition.
Safety
Causes and Fixes
Verify physical network connection - check Ethernet cable, switch port LEDs, and X120 interface connection on the NCU.
Test network connectivity by pinging the remote diagnostics server IP address from the control's commissioning mode (ping command in command line).
Check firewall settings on both the control (if Windows-based) and customer network - ensure ports 22 (SSH), 443 (HTTPS), and Siemens-specific ports are open.
Coordinate with customer IT department before modifying firewall rules.
If using VPN connection, verify VPN tunnel is active and stable, check for timeout settings, and restart VPN service if necessary.
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.