Siemens SINUMERIK codes
Siemens SINUMERIKProgram/G-codeIntermediate30-120 minutes

100932

Siemens 840D 100932 - !Error(file access): Cannot save

!Error(file access): Cannot save

Siemens SINUMERIK alarm 100932:!Error(file access): Cannot save. This alarm indicates an error condition in the NC program or control configuration that must be resolved before the operation can continue.

Root Cause Summary

Alarm 100932 indicates the control system cannot save a file to the specified destination, typically due to insufficient memory, write-protected directories, corrupted file system structures, or CompactFlash/hard disk failures. This is a file system access error that prevents the NCK or HMI from completing a write operation to permanent storage.

Safety

  • Refer to Siemens documentation
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Check available memory space: From HMI, navigate to Commissioning > Memory > Check NCK memory and CF card capacity.

  2. 2

    Delete unnecessary files: Remove obsolete part programs, old backups, or log files from the NCK user memory and CompactFlash card.

    Always verify files are backed up externally before deletion to prevent data loss.

  3. 3

    Archive existing data to external storage via network or USB interface to free up space.

  4. 4

    Attempt the save operation again and verify successful completion without alarm recurrence.

Service Recommended confidence