axismd.ai
Okuma OSP Controller
Program/G-code · Intermediate
Okuma OSP Alarm B 2464 - Spindle/turret G-code
The program contains a spindle/turret selection G-code that is invalid for the current machine configuration: either G142 was commanded on the A-turret side, or G140/G141 was commanded on a machine that is not a sub-spindle or pick-off specification. The control rejects the block as a program error.
Okuma OSP Alarm B 2464 - Spindle/turret G-code
Spindle/turret G-code
The program contains a spindle/turret selection G-code that is invalid for the current machine configuration: either G142 was commanded on the A-turret side, or G140/G141 was commanded on a machine that is not a sub-spindle or pick-off specification. The control rejects the block as a program error.
Common Causes
Troubleshooting Steps
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.