Okuma OSP Alarm A 1742 - Chuck interlock cancel interlock
A chuck open/close interlock release command (M185 for the main spindle chuck, M247 for the sub or pickoff chuck) was executed while a required door was open, or while the spindle was still turning above the safe speed. The control blocks the interlock release to prevent the chuck being opened under unsafe conditions.
Okuma OSP Alarm A 1742 - Chuck interlock cancel interlock
Chuck interlock cancel interlock
A chuck open/close interlock release command (M185 for the main spindle chuck, M247 for the sub or pickoff chuck) was executed while a required door was open, or while the spindle was still turning above the safe speed. The control blocks the interlock release to prevent the chuck being opened under unsafe conditions.
Common Causes