Okuma OSP Alarm A 1737 - Turret unclamp interlock
A G00 rapid traverse block was executed without the M203 (turret unclamp) command in the same block, or with special motor brake control an M203 was designated where it is not allowed. This is a programming/MDI command error related to turret clamp/unclamp sequencing.
Okuma OSP Alarm A 1737 - Turret unclamp interlock
Turret unclamp interlock
A G00 rapid traverse block was executed without the M203 (turret unclamp) command in the same block, or with special motor brake control an M203 was designated where it is not allowed. This is a programming/MDI command error related to turret clamp/unclamp sequencing.