Okuma OSP Alarm A 1735 - Sub-spindle chuck pressure insufficient
The control detected that sub-spindle chuck actuating pressure dropped while the sub-spindle was rotating or while the chuck was being opened or closed. It triggers when the chuck pressure confirmation input (I/O check NO.32 INPUT bit5, i2CPA/) stays OFF for more than 2 seconds, meaning the workpiece may not be held securely in the sub-spindle chuck.
Okuma OSP Alarm A 1735 - Sub-spindle chuck pressure insufficient
Sub-spindle chuck pressure insufficient
The control detected that sub-spindle chuck actuating pressure dropped while the sub-spindle was rotating or while the chuck was being opened or closed. It triggers when the chuck pressure confirmation input (I/O check NO.32 INPUT bit5, i2CPA/) stays OFF for more than 2 seconds, meaning the workpiece may not be held securely in the sub-spindle chuck.
Common Causes
Troubleshooting Steps