Okuma OSP Alarm A 1700 - Emergency stop
Okuma alarm 1700 indicates the pallet changer system failed to complete a required sequence step within the programmed timeout period. Most commonly caused by faulty proximity switches not confirming pallet position or clamp status, or hydraulic/pneumatic pressure issues preventing proper pallet seating. Typical fix involves checking APC I/O status and verifying mechanical operation of the pallet changer components.
Okuma OSP Alarm A 1700 - Emergency stop
Emergency stop
An emergency stop button is pressed, dropping the machine into emergency stop state with code 1. All motion is halted until the button is released and control power is re-established.
Root Cause Summary
Okuma alarm 1700 indicates the pallet changer system failed to complete a required sequence step within the programmed timeout period. Most commonly caused by faulty proximity switches not confirming pallet position or clamp status, or hydraulic/pneumatic pressure issues preventing proper pallet seating. Typical fix involves checking APC I/O status and verifying mechanical operation of the pallet changer components.
Safety
Causes and Fixes
Check APC I/O status
Navigate to DIAGNOSIS > I/O DIAGNOSIS > APC I/O screen. Monitor the pallet clamp and unclamp confirmation inputs while manually cycling the clamps to verify switch operation.
The clamp confirmation signals should toggle cleanly without flickering
Inspect proximity switches
Physically check the pallet clamp confirmation proximity switches for proper mounting distance (typically 2-4mm gap), contamination, or damage. Clean switches and verify LED indicators activate properly.
Ensure machine is in safe state and follow LOTO procedures before accessing APC area
Verify switch wiring
Check continuity and proper voltage at the proximity switch connectors. Verify connections are tight and cables are not damaged or pinched in the APC mechanism travel path.
Adjust APC timeout parameters
If switches are confirmed good but slow to respond, check APC-related timer parameters in the machine parameter section and increase timeout values if necessary.
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.