Okuma OSP codes
Okuma OSPSafetyIntermediate20 - 60 minutes

1700

Okuma OSP Alarm A 1700 - Emergency stop

Emergency stop

An emergency stop button is pressed, dropping the machine into emergency stop state with code 1. All motion is halted until the button is released and control power is re-established.

Root Cause Summary

Okuma alarm 1700 indicates the pallet changer system failed to complete a required sequence step within the programmed timeout period. Most commonly caused by faulty proximity switches not confirming pallet position or clamp status, or hydraulic/pneumatic pressure issues preventing proper pallet seating. Typical fix involves checking APC I/O status and verifying mechanical operation of the pallet changer components.

Safety

  • Keep clear of pallet changer
  • DANGER: Stay clear of pallet changer during operation and troubleshooting
  • Keep clear of the pallet changer during operation and troubleshooting. Unexpected movements can cause serious injury.
  • Disconnect power to the pallet changer before performing any mechanical or electrical repairs. Lockout/Tagout procedures must be followed.
  • Hydraulic systems operate under high pressure. Relieve pressure before disconnecting any hydraulic lines. Wear appropriate personal protective equipment (PPE), including safety glasses and gloves.
  • Be aware of pinch points and moving parts when working around the pallet changer.
  • Ensure the pallet is securely clamped before releasing any brakes or locks.
  • If the pallet changer uses compressed air, ensure the air supply is shut off and the system is depressurized before working on pneumatic components.
  • Consult the machine's safety manual for specific safety precautions related to the pallet changer.
  • Always perform lockout/tagout procedures before starting any checks.

Causes and Fixes

  1. 1

    Check APC I/O status

    Navigate to DIAGNOSIS > I/O DIAGNOSIS > APC I/O screen. Monitor the pallet clamp and unclamp confirmation inputs while manually cycling the clamps to verify switch operation.

    The clamp confirmation signals should toggle cleanly without flickering

  2. 2

    Inspect proximity switches

    Physically check the pallet clamp confirmation proximity switches for proper mounting distance (typically 2-4mm gap), contamination, or damage. Clean switches and verify LED indicators activate properly.

    Ensure machine is in safe state and follow LOTO procedures before accessing APC area

  3. 3

    Verify switch wiring

    Check continuity and proper voltage at the proximity switch connectors. Verify connections are tight and cables are not damaged or pinched in the APC mechanism travel path.

  4. 4

    Adjust APC timeout parameters

    If switches are confirmed good but slow to respond, check APC-related timer parameters in the machine parameter section and increase timeout values if necessary.

DIY Feasiblehigh confidence

Call a technician if:

  • ·Hydraulic system repairs needed
  • ·Mechanical alignment issues beyond adjustment
  • ·Ladder logic programming required
  • ·Multiple proximity switches failing simultaneously

Prevention

  • Perform regular cleaning of proximity switches in APC area
  • Monitor hydraulic pressure and fluid condition during PM
  • Keep backup of machine parameters including APC settings
  • Check door interlock operation during routine safety inspections

Common Mistakes

  • Not checking mechanical binding before replacing proximity switches
  • Ignoring hydraulic pressure drops during APC operation
  • Modifying APC timeout parameters without addressing root cause
  • Assuming all proximity switches failed when issue is pressure-related

Related Alarms

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.