Okuma OSP codes
Okuma OSPServo/AxisIntermediate

1697

Okuma OSP Alarm A 1697 - MCS Linear scale 2 error

MCS Linear scale 2 error

The MCS detected illegal data coming from linear scale 2 (HEIDENHAIN) on the axis shown in the object field. The scale is communicating but the position data it sends is invalid.

Common Causes

  • Defective HEIDENHAIN linear scale 2 sending corrupt data
  • Damaged scale cable or poor shielding letting noise corrupt the data
  • Contamination on the scale tape or readhead

Troubleshooting Steps

  1. 1Identify the axis from the object field, then lock out power before handling scale connectors.
  2. 2Reseat the linear scale 2 (HEIDENHAIN) connector and inspect the cable run for crushing, coolant soak, or chafing.
  3. 3Clean the scale tape and readhead window with the approved cleaner; contamination is a common cause of illegal data.
  4. 4Check that the scale cable shield is properly grounded at the drive end.
  5. 5If the illegal data error persists with verified cabling and a clean scale, the corrective action is to change linear scale 2 (HEIDENHAIN) per the manual.

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.