axismd.ai
Okuma OSP Controller
Parameter · Intermediate
Okuma OSP Alarm A 1323 - Illegal YS-axis position
An axis movement command was executed while the YS axis was not at the spindle-center (turning) position stored in the system parameter, even though the machine was not in Y-axis mode. On machines with the YS-axis carriage-return positioning specification, it also means a move was commanded while the YS axis was away from its carriage-return position.
Okuma OSP Alarm A 1323 - Illegal YS-axis position
Illegal YS-axis position
An axis movement command was executed while the YS axis was not at the spindle-center (turning) position stored in the system parameter, even though the machine was not in Y-axis mode. On machines with the YS-axis carriage-return positioning specification, it also means a move was commanded while the YS axis was away from its carriage-return position.
Common Causes
Troubleshooting Steps
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.