axismd.ai
Okuma OSP Controller
Overtravel/Limit · Intermediate
Okuma OSP Alarm A 1299 - Axis moved to sub-spindle interference distance
The control's interference check stopped a move because the commanded position would bring the sub-spindle headstock (W-axis) and the B-turret (ZB-axis) closer than the interference distance set in the parameter. On LT-series machines the same check runs between the L and R spindles, and on ZA-W interlock specs between the ZA-axis and W-axis. The code tells you which pair of axes violated the limit.
Okuma OSP Alarm A 1299 - Axis moved to sub-spindle interference distance
Axis moved to sub-spindle interference distance
The control's interference check stopped a move because the commanded position would bring the sub-spindle headstock (W-axis) and the B-turret (ZB-axis) closer than the interference distance set in the parameter. On LT-series machines the same check runs between the L and R spindles, and on ZA-W interlock specs between the ZA-axis and W-axis. The code tells you which pair of axes violated the limit.
Common Causes
Troubleshooting Steps
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.