Okuma OSP codes
Okuma OSPOvertravel/LimitIntermediate

1299

Okuma OSP Alarm A 1299 - Axis moved to sub-spindle interference distance

Axis moved to sub-spindle interference distance

The control's interference check stopped a move because the commanded position would bring the sub-spindle headstock (W-axis) and the B-turret (ZB-axis) closer than the interference distance set in the parameter. On LT-series machines the same check runs between the L and R spindles, and on ZA-W interlock specs between the ZA-axis and W-axis. The code tells you which pair of axes violated the limit.

Common Causes

  • Program commands W-axis or ZB-axis (or ZA-axis) into the interference zone between sub-spindle and turret
  • Interference distance parameter set too large for the actual machine layout
  • Steady rest or tailstock position command exceeding the max/min distance limits (codes 2-5)
  • Turret moved into the R-spindle interference distance (code 6)

Troubleshooting Steps

  1. 1Read the code number shown with the alarm: code 1 = Move violated the sub-spindle interference distance; code 2 = Sub-spindle move exceeded the maximum steady rest-to-tailstock distance; code 3 = Sub-spindle move exceeded the minimum steady rest-to-tailstock distance; code 4 = Steady rest move exceeded the maximum steady rest-to-tailstock distance; code 5 = Steady rest move exceeded the minimum steady rest-to-tailstock distance; code 6 = Axis moved into the interference distance between turret and R-spindle
  2. 2Read the code on the alarm screen to identify which axis pair tripped: code 1 = sub-spindle/turret interference, codes 2-5 = steady rest vs tailstock distance, code 6 = turret vs R-spindle.
  3. 3For code 1 or 6, jog the W-axis (or ZB/ZA-axis) away from the opposing headstock/turret in manual mode to clear the interference zone, then reset the alarm.
  4. 4Review the block that commanded the move and correct the W/ZB (or ZA) position so the two units stay outside the interference distance.
  5. 5For codes 2-5, check the steady rest and tailstock position commands against the maximum/minimum distance settings and correct the offending value in the program.
  6. 6If the program looks correct, verify the interference distance parameter value matches the actual machine geometry; an oversized value will trip on legitimate moves.
  7. 7If the alarm recurs with verified-correct positions and parameters, record the alarm number, code and object and contact Okuma service.

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.