Okuma OSP Alarm A 1200 - Stroke end over

Stroke end over

An axis (turret) has traveled onto the stroke end (emergency) limit. The control has stopped axis motion to prevent mechanical damage beyond the allowed travel.

Root Cause Summary

Okuma OSP Alarm 1200 indicates the turret indexing system failed to complete its positioning cycle within the programmed time limit. This typically occurs when hydraulic pressure is insufficient, position feedback sensors are faulty, or mechanical binding prevents proper turret rotation and clamping. The most common fix involves checking hydraulic pressure and cleaning/adjusting the turret position sensors.

Safety

  • Verify turret is clamped before operation
  • ⚠️ CRITICAL: Verify turret is fully clamped before starting any operation
  • Disconnect power to the machine before performing any electrical troubleshooting.
  • Be aware of potential pinch points during turret movement. Keep hands and tools clear.
  • If the turret is hydraulically or pneumatically powered, relieve pressure before disconnecting any lines.
  • Use proper lifting techniques when handling heavy turret components.
  • Ensure the machine is properly grounded to prevent electrical shock.
  • Always power down and lock out the machine before performing any troubleshooting steps to prevent accidental activation.

Causes and Fixes

  1. 1

    Check Hydraulic Pressure Gauge

    Verify hydraulic system pressure at the main gauge. Normal operating pressure should be 500-700 PSI for most Okuma turret systems. If pressure is below 400 PSI, the turret cannot function properly.

    Ensure machine is in emergency stop before checking hydraulic connections

  2. 2

    Inspect Hydraulic Filter

    Check the hydraulic filter for contamination. A clogged filter will cause pressure drop and slow turret response. Replace filter if dirty or if pressure differential exceeds manufacturer specifications.

    Check filter bypass valve - if it's open, the filter is likely clogged

  3. 3

    Test Turret Valve Operation

    Access the PLC ladder logic through the maintenance screen and manually activate the turret clamp/unclamp valves. Listen for valve operation and observe pressure changes to isolate faulty solenoid valves.

DIY Feasiblehigh confidence

Call a technician if:

  • ·Hydraulic system requires major repair
  • ·PLC ladder logic corruption detected
  • ·Mechanical binding requires turret disassembly

Prevention

  • Maintain proper hydraulic pressure and cleanliness
  • Regular cleaning of turret position sensors
  • Follow recommended turret lubrication schedule

Common Mistakes

  • Ignoring gradual pressure loss until complete failure
  • Cleaning sensors with machine powered on
  • Adjusting PLC timers without addressing root mechanical causes

Related Alarms

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.