Okuma OSP Alarm A 1172 - MCS Pulse generator count over
The pulse generator (PG) count value per one revolution differs from the data specified in the servo data file for the axis or spindle named in the object. The feedback device is not delivering the expected number of counts per turn, so position and speed data are wrong.
Okuma OSP Alarm A 1172 - MCS Pulse generator count over
MCS Pulse generator count over
The pulse generator (PG) count value per one revolution differs from the data specified in the servo data file for the axis or spindle named in the object. The feedback device is not delivering the expected number of counts per turn, so position and speed data are wrong.