This alarm indicates an acknowledged undervoltage condition detected in the power module of the KUKA KRC controller, affecting one or more of the specified power supply phases or rails (1224, 1225, 1226, 1227, 1228). The controller has detected that input voltage has fallen below the minimum operating threshold and requires acknowledgment to clear the alarm condition.
This alarm indicates an acknowledged undervoltage condition detected in the power module of the KUKA KRC controller, affecting one or more of the specified power supply phases or rails (1224, 1225, 1226, 1227, 1228). The controller has detected that input voltage has fallen below the minimum operating threshold and requires acknowledgment to clear the alarm condition.
Common Causes
Unstable or insufficient main power supply voltage below 380V AC (3-phase) or 110V AC (single-phase) specification
Loose or corroded electrical connections at the main power terminals or internal power module connectors
Faulty power distribution unit, circuit breaker, or power supply cable with high resistance
Defective power module capacitors or voltage regulation components experiencing degradation
Transient voltage sag caused by heavy electrical load on the facility grid or nearby equipment startup
Troubleshooting Steps
1Acknowledge the alarm using the teach pendant interface and note if the alarm immediately reoccurs or persists
2Verify main power supply voltage at the controller input terminals using a calibrated multimeter; confirm 3-phase voltage is within ±10% of nominal (typically 380-415V AC)
3Inspect all power terminal connections at the main disconnect and power module for corrosion, loose fasteners, or damaged connectors; reseat connections firmly
4Check the facility's electrical system for voltage instability or excessive load; coordinate with plant maintenance to measure grid voltage stability
5Review the power module service history and examine capacitors visually for bulging, leakage, or burn marks indicating component failure requiring replacement
6If voltage is stable and connections are secure, contact KUKA service to test or replace the power module, as internal voltage regulation circuits may be faulty