KUKA Robot KRC0153 - Accuvoltage at <kps number> below <voltage level> during last buffering

Accuvoltage at <kps number> below <voltage level> during last buffering

This alarm indicates that the accumulator (backup battery) voltage in the specified KPS (KUKA Power Supply) module fell below the minimum threshold required to safely buffer the robot controller during a shutdown sequence. The accumulator failed to maintain sufficient charge to preserve critical system states and program memory during power loss or emergency stop events.

Common Causes

  • Accumulator battery has reached end of life or is degraded
  • Insufficient charging time between power cycles or after emergency stops
  • Faulty accumulator charging circuit or voltage regulator in the KPS module
  • Poor electrical connections or corrosion on accumulator terminals
  • Repeated emergency stop activations draining accumulator charge without adequate recharge time

Troubleshooting Steps

  1. 1Check the accumulator charging status by monitoring the KPS module LED indicators and voltage readings in the controller diagnostics menu
  2. 2Allow the robot controller to remain powered on for an extended period (typically 30-60 minutes) to allow full accumulator recharge from the power supply
  3. 3Inspect all electrical connections to the KPS module and accumulator terminals for corrosion, loose contacts, or damage, and clean/reseat as needed
  4. 4Verify the KPS module voltage output and charging circuit functionality using a multimeter at the accumulator terminals
  5. 5If voltage remains low after extended charging, replace the accumulator battery module following KUKA service procedures for your specific KRC controller generation
  6. 6Perform a full system power cycle test to confirm the alarm clears and accumulator maintains proper voltage during normal operation