Heidenhain codes
HeidenhainSpindleIntermediate30-120 minutes

292-001D

HEIDENHAIN 292-001D - DCM inactive: Facing-slide kinematics are activated

DCM inactive: Facing-slide kinematics are activated

DCM monitoring is disabled because facing slide kinematics have been activated.

Root Cause Summary

Alarm 292-001D occurs when DCM (Dynamic Collision Monitoring) is automatically deactivated due to facing-slide kinematics being active in the machine configuration. The TNC system disables collision monitoring because facing-slide operations involve complex rotational movements that the standard DCM algorithms cannot properly monitor.

Safety

  • Refer to Heidenhain service manual
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Check kinematic configuration

    Access MOD function → Machine Parameters → MP7500 KINEMATICS_TYPE and verify if facing-slide kinematics are configured.

    Document current kinematic settings before making changes

  2. 2

    Review machine setup requirements

    Consult machine documentation to determine if facing-slide kinematics are actually required for current operations.

    Changing kinematic models requires machine geometry recalibration

  3. 3

    Evaluate DCM necessity

    If DCM is required, consider switching to standard 5-axis kinematics via MP7500 if machine setup permits.

    Standard kinematics allow DCM while maintaining most rotary axis functionality

DIY Feasiblehigh confidence

Call a technician if:

  • ·Kinematic model changes require machine recalibration
  • ·Uncertainty about correct kinematic configuration for specific machine

Prevention

  • Document kinematic configuration before software updates
  • Verify parameter backups include kinematic settings
  • Establish procedures for collision monitoring when DCM is unavailable

Common Mistakes

  • Attempting to manually enable DCM while facing kinematics are active
  • Changing kinematic model without proper machine recalibration
  • Ignoring collision risks when DCM protection is unavailable

Related Alarms

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.