296-0004

HEIDENHAIN 296-0004 - Process monitoring recordings are not compatible

Process monitoring recordings are not compatible

Process monitoring recordings are no longer valid because settings were changed in the machine configuration.

Safety

  • Refer to Heidenhain service manual
  • Ensure qualified technician performs repairs

Common Causes

  • Machine config changed
  • Process monitoring settings modified
  • Existing recordings invalidated

Troubleshooting Steps

  1. 1Note the full error text and the NC software number of the control.
  2. 2Delete the existing process monitoring recordings.
  3. 3Perform new reference machining operations to create valid recordings.
  4. 4Contact your machine builder or HEIDENHAIN service if assistance is needed.