Heidenhain 2A0-0007 - LSV2: Transmission error
This alarm indicates the LSV2 protocol communication layer has failed to complete a data transmission between the TNC control and an external LSV2 client device. The failure occurs when expected acknowledgment packets are not received within the protocol timeout period, or when the physical/logical network path is interrupted during active LSV2 communication.
Heidenhain 2A0-0007 - LSV2: Transmission error
LSV2: Transmission error
LSV2 (Leitstand-Verbindung 2) Transmission Error occurs when the Heidenhain control detects a communication failure over the LSV2 protocol interface. This alarm typically appears during data transfer operations between the TNC control and external devices such as PCs running TNCremo, network file transfers, or remote desktop applications attempting LSV2 communication.
Root Cause Summary
This alarm indicates the LSV2 protocol communication layer has failed to complete a data transmission between the TNC control and an external LSV2 client device. The failure occurs when expected acknowledgment packets are not received within the protocol timeout period, or when the physical/logical network path is interrupted during active LSV2 communication.
Safety
Causes and Fixes
Inspect Ethernet Cable Connection
Check the Ethernet cable connected to the X116 (TNC 320/530) or X26 (TNC 620/640) interface on the control. Verify both ends are firmly seated and link LEDs are illuminated on network hardware.
Use Category 5e or better shielded cables for LSV2 connections in industrial environments to prevent EMI interference.
Test Cable Continuity
Replace the Ethernet cable with a known-good cable. Test with a cable tester if available to verify all 8 conductors have continuity and proper pinout (T568A or T568B standard).
Verify Network Switch/Hub Operation
If using a network switch between TNC and PC, verify the switch port link lights are active. Try connecting directly point-to-point between control and PC to isolate switch-related issues.
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.