HEIDENHAIN 2A0-0005 - Data transfer erroneous
Alarm 2A0-0005 indicates a communication failure during data transfer with Block Check Character (BCC) protocol, typically occurring when the TNC receives 15 consecutive NAK signals or experiences timeout conditions. This alarm is most commonly triggered by incorrect RS232/RS422 interface settings or hardware failures in the communication chain.
HEIDENHAIN 2A0-0005 - Data transfer erroneous
Data transfer erroneous
Data transfer errors occurred during communication. Multiple transmission issues including NAK signals, baud rate mismatches, or frame errors have been detected.
Root Cause Summary
Alarm 2A0-0005 indicates a communication failure during data transfer with Block Check Character (BCC) protocol, typically occurring when the TNC receives 15 consecutive NAK signals or experiences timeout conditions. This alarm is most commonly triggered by incorrect RS232/RS422 interface settings or hardware failures in the communication chain.
Safety
Causes and Fixes
Access Interface Configuration
Press MOD key, navigate to Machine Parameters → Communication → RS232 Interface settings (typically MP7200-MP7299 range).
Document current settings before making changes for easy rollback.
Verify Baud Rate Parameter
Check MP7201 (Baud rate) setting and compare with peripheral device specification. Common values: 9600, 19200, 38400, 115200.
Incorrect baud rate changes can disrupt all serial communications.
Test Communication
Attempt data transfer operation and monitor for alarm clearance. Use TNC's built-in communication test function if available.
Start with lower baud rates (9600) and work upward for better stability.
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.