Heidenhain codes
HeidenhainParameterIntermediate30-120 minutes

293-000F

HEIDENHAIN 293-000F - The option for axis-specific jerk has not been enabled

The option for axis-specific jerk has not been enabled

Axis-specific jerk was activated in configuration but the software option is not enabled. Channel jerk is now active for this axis.

Root Cause Summary

HEIDENHAIN alarm 293-000F occurs when axis-specific jerk values are configured in machine parameters but the corresponding software option has not been enabled in the control. The TNC system detects this mismatch between configured functionality and licensed options during initialization or axis configuration changes.

Safety

  • Refer to Heidenhain service manual
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Check Software Options

    Access MOD function and navigate to Software Options menu to verify if option 'Axis-specific jerk' is enabled.

    Document current option status before making changes

  2. 2

    Verify Machine Parameters

    Check MP7230 (axis-specific jerk enable) and MP7231-7238 series for individual axis jerk settings in machine parameter menu.

    Do not modify machine parameters without proper authorization

  3. 3

    Enable Required Option

    Contact Heidenhain service to enable the axis-specific jerk option or modify machine parameters to use channel-based jerk values instead.

    Keep option enablement documentation for future reference

DIY Feasiblehigh confidence

Call a technician if:

  • ·Software option enablement required
  • ·License upgrade needed
  • ·Machine parameter backup/restore required

Prevention

  • Verify software options before configuring advanced machine parameters
  • Maintain documentation of enabled options and licenses
  • Regular backup of machine parameter settings

Common Mistakes

  • Assuming all TNC features are enabled by default
  • Modifying machine parameters without checking software options
  • Not restarting control after parameter changes

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.