HEIDENHAIN 292-0016 - DCM inactive: Axis has not yet been homed
Alarm 292-0016 occurs when the Dynamic Collision Monitoring (DCM) system cannot activate because one or more machine axes lack valid reference point data. The TNC control requires all monitored axes to have established reference positions before DCM can function properly.
HEIDENHAIN 292-0016 - DCM inactive: Axis has not yet been homed
DCM inactive: Axis has not yet been homed
Dynamic collision monitoring is inactive because one or more axes have not been homed.
Root Cause Summary
Alarm 292-0016 occurs when the Dynamic Collision Monitoring (DCM) system cannot activate because one or more machine axes lack valid reference point data. The TNC control requires all monitored axes to have established reference positions before DCM can function properly.
Safety
Causes and Fixes
Check Reference Point Status
Press REF key and observe the reference point menu. Look for axes showing red indicators or 'NOT REF' status.
Use soft key 'SHOW ALL AXES' to verify all configured axes are displayed
Execute Reference Point Search
Select unreferenced axes using arrow keys, then press NC START to begin reference point search sequence.
Ensure machine area is clear and all guards are closed before starting reference search
Verify DCM Activation
After successful referencing, check MOD function 'COLLISION MONITORING' to confirm DCM status shows 'ACTIVE'.
DCM activation may take 5-10 seconds after referencing is complete
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.