Heidenhain codes
HeidenhainServo/AxisIntermediate30-120 minutes

293-0004

HEIDENHAIN 293-0004 - Incorrect filter form in axis

Incorrect filter form in axis

This TNC7/TNC 640 error indicates a servo-related condition. Only position filters with HSC form are allowed. The control has detected an issue that requires investigation.

Root Cause Summary

Alarm 293-0004 occurs when a position filter configuration in the servo parameters is incompatible with HSC (High Speed Cutting) requirements. The TNC system requires specific filter forms for HSC operation, and non-compliant filter settings will trigger this alarm.

Safety

  • Refer to Heidenhain service manual
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Access machine parameters

    Press MOD key, select 'Machine parameters' from the menu, navigate to servo parameters section.

    Use the search function (GOTO) to quickly find MP1420 parameters

  2. 2

    Check MP1420 position filter settings

    Examine MP1420.x for the affected axis. Verify the filter type is set to HSC-compatible form (typically value 2 or 3).

    Document original values before making changes

  3. 3

    Modify filter configuration

    Change MP1420.x to HSC-compatible filter form. Consult machine documentation for approved values.

    HSC-compatible filters typically have better frequency response characteristics

  4. 4

    Restart control and test

    Perform control restart (CTRL+ALT+DEL) and test axis movement in HSC mode to verify alarm clearance.

DIY Feasiblehigh confidence

Call a technician if:

  • ·Parameter changes don't clear alarm
  • ·Servo instability after filter modification
  • ·Uncertainty about HSC requirements

Prevention

  • Document all parameter changes
  • Verify HSC compatibility before enabling
  • Maintain parameter backups
  • Follow proper commissioning procedures after hardware changes

Common Mistakes

  • Changing filter parameters without understanding HSC requirements
  • Enabling HSC without updating all related parameters
  • Using generic parameter sets for specific hardware configurations

Related Alarms

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.