Heidenhain codes
HeidenhainPower SupplyIntermediate30-120 minutes

238-1011

HEIDENHAIN 238-1011 - 1011 UVR failure of fan for power supply unit

1011 UVR failure of fan for power supply unit

The UVR power supply unit fan has failed. Cooling is compromised and may lead to overheating.

Root Cause Summary

HEIDENHAIN alarm 238-1011 indicates the UVR power supply unit has detected a fan failure or malfunction in the cooling system. This alarm triggers when the fan monitoring circuit detects insufficient airflow, fan speed below threshold, or complete fan failure in the power supply unit.

Safety

  • Refer to Heidenhain service manual
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Visual Fan Inspection

    Power down the system and visually inspect the UVR power supply fan for physical damage, debris, or seized rotor.

    Ensure complete power isolation before opening any electrical enclosures

  2. 2

    Fan Voltage Check

    Using a multimeter, verify the fan receives proper voltage (typically 24VDC) at the fan connector terminals.

    Check voltage both at rest and under load conditions

  3. 3

    Fan Replacement

    Replace the defective fan with Heidenhain-approved replacement part, ensuring proper connector orientation and mounting.

    Always use genuine Heidenhain parts to maintain proper airflow specifications

  4. 4

    Alarm Reset

    Clear the alarm via TNC control using CLEAR ALARM key and verify fan operation through diagnostic display.

    Monitor system for 30 minutes to ensure stable operation

DIY Feasiblehigh confidence

Call a technician if:

  • ·UVR control board replacement required
  • ·Multiple power supply alarms present
  • ·Thermal damage to power components detected

Prevention

  • Regular filter cleaning every 3-6 months
  • Monitor UVR temperatures through TNC diagnostics
  • Maintain proper ventilation clearances
  • Perform annual fan operation verification

Common Mistakes

  • Ignoring airflow obstructions
  • Using non-approved replacement fans
  • Failing to check load conditions
  • Not verifying proper connector orientation after service

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.