HEIDENHAIN 238-101B - 101B UVR value of DC-link center voltage too high

101B UVR value of DC-link center voltage too high

The UVR DC-link mean voltage has reached impermissibly high values. The center voltage is exceeding safe limits.

Root Cause Summary

Alarm 238-101B indicates the UVR power supply unit has detected DC-link center voltage exceeding safe operating limits. This typically occurs due to regenerative energy feedback during rapid deceleration, power supply component failure, or incorrect machine parameter configuration affecting the drive system's energy management.

Safety

  • Refer to Heidenhain service manual
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Check acceleration parameters

    Navigate to MOD > Machine Parameters > Axis-specific parameters and verify acceleration/deceleration values for affected axes are within manufacturer specifications.

    Reduce deceleration rates by 20-30% initially to test if alarm clears

  2. 2

    Inspect regenerative resistor circuit

    Verify regenerative brake resistor connections and resistance values match UVR power supply specifications. Check for burnt or damaged resistors.

    Ensure power is OFF and capacitors are discharged before checking resistor circuits

  3. 3

    Monitor DC-link voltage during operation

    Use TNC diagnostic screen to monitor real-time DC-link voltage values during normal machining cycles to identify voltage spike patterns.

    Access via PLC > Status > Drive diagnosis for real-time voltage monitoring

Service Recommendedmedium confidence

Call a technician if:

  • ·UVR unit replacement required
  • ·DC-link capacitor replacement needed
  • ·Power supply parameter modifications required
  • ·Electrical system modifications needed

Prevention

  • Regular power quality monitoring
  • Gradual acceleration/deceleration programming
  • Annual UVR preventive maintenance
  • Proper machine parameter backup procedures

Common Mistakes

  • Ignoring regenerative resistor maintenance
  • Modifying power parameters without documentation
  • Operating with unstable input power
  • Delaying UVR replacement when fault indicators present